• Simple to use
• Ideal for mixed MMF &
SMF testing
• Up to 6 mixed LED, Laser
& VFL sources
• Excellent optical power
stability
• Excellent re-connection
repeatability
• LCD is large, clear,
sunlight readable & backlit
• Autotest compatibility with
other instruments
• Optical test tone with
Multi-Fiber ID function
• VisiTester easily identifies
active test channel
• Interchangeable connectors
with dust cap / tilt bail
• Encircled Flux compliant
multimode LED sources
• Multimode sources supplied
with mandrel wraps
• KI 2400 series is
ultra-stable with zero warm up
• Long battery life
• External power / charging
via USB
• 3 ~ 7 Year warranty
• 3 year calibration cycle
• Made in Australia
KI 2400/2800 Series - Hand Held
Fiber Source
The KI2400 / 2800 Hand Held Fiber Sources are used
with optical power meters for testing optical loss on single mode and multimode
fibers. A Multi-Fiber tone feature makes for handy continuity / polarity
testing and fault finding, also for use with clip-on traffic identifiers.
The KI2800 source provides excellent general test
capability. Alternatively, the KI2400 premium source is unique in the industry,
with zero warm up, ultrahigh stability, and is unaffected by varying back reflection.
All emitters feature excellent repeatability and
stability. Re-connection repeatability is < 0.1 dB, resulting in exceptional
test accuracy.
This instrument meets the general requirements of MIL
PRF 28800F class 2. The large display provides the user with an easy view of
instrument status and test results.
Practical interchangeable optical connectors are
easily changed, and are protected with a captive dust cover / tilt bail. Metal
free adaptors help avoid contamination of connectors in high power systems.
AA alkaline batteries have long life, and the micro
USB power input ensures high availability. Or use rechargeable batteries with
built-in charging.
When used with a Kingfisher Autotest compatible power
meter or loss test set, automatic l identification is achieved, and the nominal source
power is displayed on the power meter.
Up to 6 LED / laser sources can be specified, making
this a versatile test source for mixed multimode / single mode fiber testing.
Laser options compliant with CWDM standards cover
typical cable qualification for O, E, S, C, & L bands, including the water
absorption peak, 1625 nm.
Multimode LED sources are Encircled Flux (EF)
standards compliant, to provide the most consistent and reliable testing
results.
The unique VisiTester option mixes a laser VFL with
Autotest, so at the power meter end, the active test fiber winks, making it
obvious to the user. It also extends practical fault finding options.
Please refer to other brochures for our convenient
FiberTester kits, comprising groups of instruments and common accessories
supplied in a protective field carry case.
OPTICAL Specifications
|
1310/1550
nm Laser
|
CWDM1Laser
|
1625
nm Laser
|
650
nm VisiTester2
|
850
/ 1300 nm LED
|
1310/1550
nm LED
|
470
/ 520 nm LED
|
Comments
|
KI 2800 series
|
Short term stability (dB)
|
0.04
|
0.06
|
0.06
|
N/A
|
0.01
|
N/A
|
0.01
|
For 15 min, typical ±D 2°C, after warm up, ORL < -25 dB
|
Stability over temp (dB)
|
0.6
|
0.6
|
0.6
|
N/A
|
0.35
|
N/A
|
0.35
|
Typical
|
Premium zero warm up & ultra-stable KI 2400
series3
|
Short term stability (dB)
|
0.03
|
0.05
|
0.05
|
N/A
|
0.01
|
0.03
|
N/A
|
For 15 min, max, ±D 3°C no warm- up
|
Stability over temp (dB)
|
0.2
|
0.2
|
0.2
|
N/A
|
0.35
|
0.2
|
N/A
|
Max
|
Common for both KI 2400 & KI 2800 series
|
l initial tolerance (nm)
|
20
|
6.5
|
20
|
5
|
NA
|
20
|
15
|
At 25 °C
|
l width, nm
|
3
|
<
1
|
3
|
3
|
NA
|
35
/ 48
|
25
|
FWHM, typical
|
l nm/°C
|
0.4
|
0.1
|
0.4
|
0.1
|
0.4
|
0.4
|
N/A
|
Typical
|
Mode Controlled Source
|
N/A
|
N/A
|
N/A
|
N/A
|
Mode
controlled
|
N/A
|
N/A
|
50/125 compliant: IEC
61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178.
|
Reconnection repeatability4 dB
|
0.1
|
0.1
|
0.1
|
0.1
|
0.05
|
0.1
|
N/A
|
95 % confidence
|
Modulation
|
270
Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones, 2 Hz
blink for VisiTester
|
|
Output power level
|
Refer
to ORDERING INFORMATION section for output power level of specific model
|
Laser: adjustable over 7
dB in 0.01 dB steps, LED: fixed
|
Output power accuracy
|
± 1 dB (for Laser/eLED @ SMF, Multimode LED @
62.5 µm, POF @ 1 mm)
|
|
Class 1 Laser / LED infra-red device. Compliant with
IEC60825-1.
Note 1: CWDM laser wavelengths:
1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510,
1530, 1550, 1570, 1590, 1610 nm
Note 2: VisiTester option:
|
|
The
unique VisiTester option mixes a laser VFL with Autotest, so at the power
meter end, the active test fiber winks, making it obvious to the user. It
also extends practical fault finding options.
|
|
Note 3:
Premium Zero Warm Up & Ultra Stable KI2400 Series
Note 4:
Reconnection Repeatability:
KI 2400 & KI 2800 light sources achieves very high reconnection repeatability
of 0.1 dB, which provides steady output power every time connecting the
light sources.
|
|
GENERAL SPECIFICATIONS
Parameters
|
Value
|
Parameters
|
Value
|
Battery life
|
Laser/LED source: 90/80 hours in Autotest, typical
|
Dust cap
|
Captive, functions as tilt bail when slid open
|
Size
|
190
x 105 x 35 mm (7.5 x 4.1 x 1.4”)
|
Operating / Storage
|
-15 to 55 °C / -25 to 70 °C
|
Weight
|
420
gm (0.9 lb.). Shipping 1.5 Kg (3.3 lb.)
|
Relative humidity
|
0 ~ 95 %
|
LCD size
|
74
x 55 mm / 2.9 x 2.2”
|
Calibration cycle
|
3 years
|
Case
|
Polycarbonate / rubber
edges & corners, moisture resistance, 1-meter drop tested
|
Power
|
2 Alkaline AA cells or
2 x NiMH AA cells, user selectable charging; Ext power input via micro USB;
Selectable auto-off, low battery indicator, backlit display
|
Australian and international patents. Technical data is subject to
change without notice as part of our program of continuous improvements.
ORDERING INFORMATION
Please enquire for non-listed
specifications such as: Wavelengths,
Power levels, PC / APC Connectors
Description
|
Power
(dBm) @ Fiber Type(mm)
|
|
Ports
|
P/N
|
|
Laser
|
LED
|
VisiTester
|
|
|
|
SMF
|
SMF
|
50m
|
62.5m
|
1
mm
|
SMF
|
|
|
KI 2800 series
|
|
|
Instrument, Source
850-1300 nm LED
|
-
|
-32
|
-22.5
|
-20
|
-
|
-
|
1
|
KI 2803
|
Instrument, Source
850-1300 nm LED VisiTester
|
-
|
-35
|
-25.5
|
-23
|
-
|
+2
|
1
|
KI 28603
|
Instrument, Source 470-520
nm LED
|
-
|
-
|
-
|
-
|
-6
|
-
|
2
|
KI 2806
|
Instrument, Source
1310-1550 nm Laser
|
0
|
-
|
-
|
-
|
-
|
-
|
1
|
KI 2822
|
Instrument, Source
1310-1550 nm Laser VisiTester
|
-3
|
-
|
-
|
-
|
-
|
+2
|
1
|
KI 28622
|
Instrument, Source
850-1300 nm LED, 1310-1550 nm Laser
|
0
|
-32
|
-22.5
|
-20
|
-
|
-
|
2
|
KI 2824
|
Instrument, Source
850-1300 nm LED, 1310-1550 nm Laser APC
|
0
|
-32
|
-22.5
|
-20
|
-
|
-
|
2
|
KI 2824-APC
|
Instrument, Source
850-1300 nm LED, 1310-1550 nm Laser VisiTester
|
-3
|
-32
|
-22.5
|
-20
|
-
|
+2
|
2
|
KI 28624
|
Instrument, Source
850-1300 nm LED, 1310-1550 nm Laser VisiTester APC
|
-3
|
-32
|
-22.5
|
-20
|
-
|
+2
|
2
|
KI
28624-APC
|
Instrument, Source 850-1300
nm LED, 1310-1550-1625 nm Laser
|
-3
|
-32
|
-22.5
|
-20
|
|
+2
|
2
|
KI 2825-APC
|
Instrument, Source
850-1300 LED VisiTester, 1310-1550 Laser VisiTester
|
-3
|
-35
|
-25.5
|
-23
|
|
+2
|
2
|
KI 28634
|
Instrument, Source
1310-1550-1625 nm Laser APC
|
-3
|
-
|
-
|
-
|
|
-
|
1
|
KI
28010-APC
|
Instrument, Source
1310-1550-1625 nm Laser VisiTester APC
|
-7
|
-
|
-
|
-
|
|
+2
|
1
|
KI
28610-APC
|
Instrument, Source
1310-1490-1550-1625 nm Laser APC
|
-3
|
-
|
-
|
-
|
|
-
|
1
|
KI
28016-APC
|
Zero warm up &
ultra-stable light sources, KI 2400 series
|
Instrument, Source
1310-1550 nm Ultra Stable eLED
|
-
|
-20
|
-
|
-
|
|
-
|
1
|
KI 2419
|
Instrument, Source
1310-1550 nm Ultra Stable Laser
|
-4
|
-
|
-
|
-
|
|
-
|
1
|
KI 2422
|
Instrument, Source
1310-1550-1625 nm Ultra Stable Laser APC
|
-7
|
-
|
-
|
-
|
|
-
|
1
|
KI
24010-APC
|
STANDARD ACCESSORIES
Description
|
Quantity
|
SC connector adaptor (OPT046)
|
1 per port
|
Operation manual
QA certificate
Calibration certificates
|
1
1
1 set
|
Carry Pouch
Carry strap
50 & 62.5 µm fiber mandrel wrap set for Multimode sources
(OPT701)
|
1
1
1
|
USB-A to USB-micro type cable
|
1
|
|
This
instrument is supplied with metal-free sleeve
interchangeable optical connector adaptors. The ferrule type is fixed and
customer specified as either PC or APC. Green is associated with APC. You can
order any number of connector adaptors.
OPTIONAL ACCESSORIES
Description
|
Part number
|
Carry Case for 2
Instruments
|
OPT153
|
Carry Case includes
Cletop-style cleaner & Cleaning Sticks
|
OPT154B
|
OPTIONAL INTERCHANGEABLE
CONNECTOR ADAPTORS
|
|
Note 5: For Mini Toslink, unterminated POF cable, HFBR series (simplex and
duplex), 2.5mm. The user turnsthe turret to the required hole size. Actual
hole size 3.85, 3.5, 3.2, 2.55, 2.4, 2.3 mm x 8.5 mm deep
|
|
Description
|
Part number
|
Description
|
Part number
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/FC
|
OPT051
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/MU
|
OPT080
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/ST
|
OPT040
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/LSA-DIN47256
|
OPT071
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/D4
|
OPT055
|
Option,
Hybrid Adaptor, Metal Sleeve, SC/SMA 905/906
|
OPT082
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/E2000
|
OPT060
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/Universal 1.25 mm
|
OPT084
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/E2000 Green
|
OPT060G
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/F3000 or LC Simplex, plastic body
|
OPT072
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/LC, metal body
|
OPT076
|
Option,
Hybrid Adaptor, Ceramic Sleeve, SC/Universal 2.5 mm
|
OPT081
|
Option,
Hybrid Adaptor, SC/POF multi
|
OPT0775
|
|
|
History
Record
Revision
|
Date
|
Editor
|
Change Description
|
19
|
27/02/2017
|
TO Ng
|
1.
Added adaptor, OPT077 (Option, Hybrid Adaptor, SC/POF multi) inn OPTIONAL
INTERCHANGEABLE CONNECTOR ADAPTOR table.
|
|