Superior measurement confidence is achieved through a combination of
excellent basic accuracy, intuitive use and rugged reliability.
Options cover power levels from +33 to -70 dBm, all useful wavelengths,
many connector styles including duplex / ribbon, and large core POF fiber.
Features
• Reliable, rugged & versatile
• Simple to use
• Very long battery life
• LCD is
large, clear, sunlight readable & backlit
• Interchangeable
connectors with dust cap/tilt bail
• 28
genuine 1% calibration wavelengths
• External
power / charger via micro USB port
• Memory
with text, timestamp and USB dump
• Simultaneous
3 λ loss display with Autotest source
• Flexible
real-time PC reporting software
• Multi-Fiber
ID tone for fiber identification
• Optional
visual fault finder
• Power
averaging mode for modulated signal
• Max /
Min recording
• 3 years calibration cycle
• External power / charging
via USB
• 3 ~ 7 Year warranty
• Made in Australia
KI 2600 Series - Hand Held Fiber Meter
The KI 2600 Hand Held Fiber Meter measures
absolute or relative light levels and test tones in fiber optic systems.
Autotest provides fast, easy and automatic
multi λ (wavelength) loss testing up to 6 λ, with up to 3 λ displayed
simultaneously, along with the respective source nominal power levels. Any
Kingfisher Autotest light source/LTS with matching λ can be used.
The meter displays mW, µW, nW, dB, dBm to
0.01 dB resolution, with no range changing delays. A separate reference for
each λ is stored and displayed. Superior high power performance is achieved.
Unique in the industry, the tight Total
Uncertainty specification covers all power levels, temperatures, connectors and
fibers, without warm up or user dark current offset.
Interchangeable connectors are dust and drop
protected. SC adaptors are supplied, with others available including small form
factor LC styles. Metal free adaptors avoid contamination of connectors in high
power systems.
Loss test results can be stored in the large memory, along with a
user-input cable name and timestamp. Results can be copied onto a USB memory
key with one button push. Alternatively, live readings can be put directly onto
a customer report computer using KITS™ customizable Excel-based reporting
software. Reports can be easily customized for any terminology, language or format. KITS™ also provides a one-button file dump to
a PC with Windows OS.
When used with Multi-Fiber ID sources, the Multi-Fiber ID tone
feature uniquely identifies up to 12 fibers, in addition to common test tones.
The VFL (Visible Fault Locator) option offers simple fault finding
and continuity testing.
Flexible power options include a choice of batteries, with a jumper
selectable battery charger. External power is via USB.
See alternative brochure for instrument versions with large area
detectors up to +33 dBm. For use with e.g. ribbon fiber, MPO/MT/MTP and MTRJ,
large core fiber such as POF, fiber bundles, high power pump lasers, other
general optical applications etc.
Specifications
Response
l
nm
|
Damagelevel
dBm
|
Calibration l
nm
|
Power
range
dBm
|
Tone
&Autotest
Min
dBm
|
Midrange
linearity1
dB
|
Calibration
Accuracy2
%
|
Polarization
Sensitivity
dB
|
Total
Uncertainty
dB 3,5
|
l
Sensitivity
±
30 nm5 dB
|
InGaAs detector
|
600 ~ 1700
|
+15
|
780, 820, 850, 980
1270, 1290, 1300, 1310, 1330, 1350,
1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610,
1625, 1650
|
+10 ~ -60
+10
~ -70
|
-45
-50
|
0.02
|
1
%
(0.06 dB)
|
<
0.005
|
0.3
|
0.03
|
H5 (InGaAs) detector
|
800 ~ 1700
|
+274
|
820, 850, 980
1270, 1290, 1300, 1310, 1330, 1350,
1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610,
1625,
1650
|
+24 ~ -50
+24
~ -60
|
-35
-40
|
0.02
|
1
%
(0.06 dB)
|
<
0.005
|
0.35
|
0.03
|
Ge detector
|
600 ~ 1650
|
+25
|
635, 650, 660, 780, 820, 1590, 1610,
1625, 1650
850, 980, 1270, 1290, 1300, 1310,
1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570
|
+15 ~ -50
+15 ~ -60
|
-40
-50
|
0.04
|
1
%
(0.06 dB)
|
<
0.005
|
0.5
|
0.03
|
|
|
|
|
|
typical
|
|
typical
|
max
|
typical
|
Note 1: Midrange linearity excludes top 5 dB and bottom 10
dB of range.
Note 2: Calibration condition: non coherent light, -35±5 dBm, 23±1°C, ±1 nm, 10±3 nmFWHM, PC ceramic connector, 100 mm fiber.
Note 3: Includes
contributions of: varying optical connector types, calibration uncertainty,
linearity over temperature & range, and fiber core diameter up to 200 mm
|
Note
4: H5 can sustain the
damage level for 2 minutes.
Note
5: At calibration wavelengths in bold type.
|
VFL Specifications
Parameters
|
Value
|
Output
power
|
+2 ± 1 dBm
|
Wavelength
|
650 nm
|
l width
|
3 nm
|
Modulation
|
CW, 2, 270, 1k, 2k Hz
|
Australian
and international patents. Technical data is subject to change without notice
as part of our program of continuous improvements. The visible laser is a Class
1 Laser product compliant with IEC60825-1 and 21CFR1040.10.
GENERAL
Specifications
Parameters
|
Values
|
Battery
life
Size
/ Weight
LCD
size
|
Up to 1000 hours laser & backlit off / 200 hours laser
in blink mode
190 x 105 x 35 mm (7.5 x 4.1 x 1.4”) / 420 gm (0.9 lb.).
Shipping 1.5 Kg (3.3 lb.)
74 x 55 mm / 2.9 x 2.2”
|
Operating
/ Storage
Relative
humidity
Case
Dust
cap
Tone
detection
|
-15 to 55 °C / -25 to 70 °C
0 ~ 95 %
Polycarbonate
/ rubber edges & corners, moisture resistance, 1-meter drop tested
Captive, functions as tilt bail when slid open
150 ~ 9900 Hz ± 1 %
|
Max
/ min
Power
|
Recording feature for stability testing
2 x
Alkaline / Lithium AA cells or 2 x
NiMH AA cells, user selectable charging; Ext power input via micro USB;
Selectable auto-off, low battery indicator, backlit display
|
Memory
USB
interfaces
Calibration
cycle
|
1000
4-λ tests with date & time in internal memory, unlimited on USB memory
key
USB-micro
typeconnector for general USB & power; USB-A type connector for memory
key only
3 years
|
ORDERING
INFORMATION
Description
|
Part
Number
|
Instrument, Power Meter
InGaAs
|
KI2600-InGaAs
|
Instrument, Power Meter
InGaAs, VFL
|
KI2601-InGaAs
|
Instrument, Power Meter
H5
|
KI2600-H5
|
Instrument, Power Meter
H5, VFL
|
KI2601-H5
|
Instrument, Power Meter
Ge
|
KI2600-Ge
|
Instrument, Power Meter
Ge, VFL
|
KI2601-Ge
|
Please enquire for non-standard specifications
STANDARD
ACCESSORIES
Description
|
Quantity
|
KI 2600 series
|
KI 2601 series
|
SC
connector adaptor (OPT046)
|
1
|
2
|
Operation
manual
|
1
|
QA
certificates
|
1
|
Calibration
certificate
|
1
|
Carry
Pouch (OPT149)
|
1
|
Carry
strap
|
1
|
USB-A
to USB-micro type cable
|
1
|
KITS™
Recording/Reporting software
|
Download from website for free
|
OPTIONAL
ACCESSORIES
Description
|
Part
number
|
Option,
Carry Case, KI2x/KI7x/KI3x, small (Carry Case for 2 Instruments)
|
OPT153*
|
Option,
Carry Case, Cletop, Cleaning Sticks, KI2x / KI9x, large
|
OPT154B*
|
Please visit kingfisherfiber.com for a wide
range of FiberTester kits.
OPTIONAL
INTERCHANGEABLE CONNECTOR ADAPTORS
Description
|
Part number
|
Description
|
Part number
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/FC
|
OPT051
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/E2000
|
OPT060
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/LC, metal body
|
OPT076
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/E2000 Green
|
OPT060G
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/ST
|
OPT040
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/Universal 1.25 mm
|
OPT084
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/D4
|
OPT055
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/Universal 2.5 mm
|
OPT081
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/MU
|
OPT080
|
Option, Hybrid Adaptor,
Metal Sleeve, SC/SMA 905/906
|
OPT082
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/LSA-DIN47256
|
OPT071
|
Option, Hybrid Adaptor,
Ceramic Sleeve, SC/F3000 or LC Simplex, plastic body
|
OPT072
|
The power meter works with both PC and APC connectors.
History Record
Revision
|
Date
|
Editor
|
Change Description
|
16
|
Jul 2016
|
TO Ng
|
In SPECIFICATIONS section:
Changed,
“Note 3: Includes
contributions of: varying optical connector types, calibration uncertainty,
full temperature, dynamic range and fiber core diameter up to 200 um.”
to,
“Note 3: Includes
contributions of: varying optical connector types, calibration uncertainty, linearity over temperature & range, and fiber
core diameter up to 200 mm.”
Reason of change: Detector’s responsivity linearity over
temperature affect the power measurement uncertainty; see attachment……
|
|