• Continuity
testing
• Visual
Fault Finder (VFL) option
• General
testing & maintenance
The KI 9800A series Shirt-pocket Fiber Source
is used to test optical loss, multi-fiberpolarity checking or fault finding in all
optical fiber systems, at 1 to 3wavelengths.
High productivity, high stability, rugged
construction and ease of use combine to achieve superior measurement
confidence.
Features
• Source or VFL options for
all fiber types
•Rugged shirt-pocket size with spring clip
• Excellent optical power stability
• Excellent re-connection repeatability
• Interchangeable connectors
• Long battery life
• Low-skill Limited Feature mode
• Multi-Fiber ID tone source feature
• Mode controlled multimode sources
• Eye-safe long distance VFL to 10Km
• Autotest compatibility with other instruments
• Large sunlight readable display
• 3-year warranty&calibration cycle
• Made in Australia
KI 9800 Series -Optical Light
Source
The KI 9800A Pocket Fiber Source is used for loss
testing, polarity checking or fault finding on single mode, multimode, PCS or
plastic optical fiber (POF) cable.
Tough construction includes general moisture
resistance, rubber corners and proven ability to withstand drops of over 2
meters onto a hard surface. It meets the general requirements of MIL PRF 28800F
Class 2.
Interchangeable optical connectors are dust and drop
protected. An SC adaptor is supplied; other styles include the popular LC. Use
of metal-free adaptors avoids contamination of connectors in high power systems.
Reconnection repeatability is < 0.1 dB, resulting in
exceptional practical source stability.
When used with an Autotest compatible Power Meter or
Loss Test Set, one button multi-wavelength loss testing is achieved.
Test tones can be used with a compatible Power Meter or
clip on identifier for fiber detection, polarity checking, fault finding and
route location.
When used with a Multi-Fiber ID compatible Power Meter,
multiple sources can be set up to uniquely identify up to 12 fibers at a time.
1310 / 1490 / 1550 / 1625 nm laser sources are ideal
for single-mode testing, with KI 9600 or KI 2600 series power meters.
850 / 1300 nm LED sources are ideal for multimode
testing, in combination with KI 9600 or KI 2600 series power meters. They meet
the Encircled Flux (EF) standard compliance to provide the most consistent and
reliable testing results.
650 / 660 nm LED source optionsare ideal for POF
testing, in combination with the KI 9600XL or KI2600XL series power meters.
The 850 nm VCSEL source for multimode fiber testing
should only be used to meet special requirements.
The 635 nm laser VFL Visual Fault Locator with Class 1
eye safety is optimized for maximum visibility on short distance applications.
The 650 nm laser VFL Visual Fault Locator with Class 2M
eye safety is optimized for long distance applications up to 10 Km. Both VFL options
offer much improved eye safety compared to pen-style units when unplugged, and
featurePC or APC interchangeable / replaceable connectors, tone / wink
function, rugged case and AAA batteries.
A Limited Feature Mode enables a site manager to lock
and track instrument settings to reduce measurement skill, and improve both
test confidence and traceability.
OPTICAL Specifications
|
1310
or 1310/1550 nm Laser
|
1310/1625
nm Laser
|
1310/1490/
1550 nm Laser
|
1310/1550/
1625 nm Laser
|
635
nm
Laser
|
650
nm
Laser
|
850
nm VCSEL
|
850
/ 1300 nm
LED
|
660
nm
LED
|
Comments
|
Output power (dBm) @ Fiber
Type (mm)
|
0@
9/125
|
0@
9/125
|
-4@
9/125
|
-4@
9/125
|
-2@
9/125
|
+7@9/125
|
-2@
62.5/125
|
-20@
62.5/125
-22.5
@ 50/125
-321 @ 9.5/125
|
-6@
1 mm POF, -13@ 200 PCF
|
± 1 dB3
|
Short term stability (dB)
|
0.041
|
0.061
|
0.041
|
0.061
|
N/A
|
N/A
|
0.121
|
0.01
|
0.01
|
For 15 min, typical ±D 2°C, after warm up
|
Stability over temp (dB)
|
0.6
|
0.6
|
0.6
|
0.6
|
N/A
|
N/A
|
0.8
|
0.35
|
0.35
|
Typical,
over temperature
|
l initial tolerance (nm)
|
20
|
20
|
20
|
30
|
5
|
5
|
20
|
N/A
|
15
|
At
25 °C
|
l width, nm
|
3
|
3
|
3
|
3
|
3
|
3
|
<
1
|
N/A
|
25
|
FWHM,
typical
|
l nm/°C
|
0.4
|
0.4
|
0.4
|
0.4
|
0.1
|
0.1
|
0.1
|
0.4
|
NA
|
Typical
|
Mode Controlled Source
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
N/A
|
Mode
controlled2
|
N/A
|
|
Reconnection
repeatability (dB)
|
0.1
|
0.1
|
0.1
|
0.1
|
0.1
|
0.1
|
0.1
|
0.05
|
N/A
|
95
% confidence
|
Modulation
|
270
Hz, 1 kHz, 2 kHz ± 2 %
|
Blinking 2 Hz
|
N/A
|
N/A
|
N/A
|
N/A
|
Yes
|
Yes
|
N/A
|
N/A
|
Yes
|
|
Output power level
|
|
Adjustable
over 3 dB in 0.1 dB steps
|
Fixed
|
Fixed
|
Fixed
|
|
Note 1: ORL
< -25 dB
Note 2: Multimode
source mode distribution @ 50/125 is compliant with the following standards:
IEC 61280-4-1 {Ed.1.0}, TIA/EIA 526-14A and TIA TSB-178.
Note 3: Only applicable to outputs @ fiber types, 9/125 mm,
62.5/125 mm, 1
mm POF. Accuracy for output @ 200 mm PCF is ± 2 dB.
GENERAL
Specifications
Parameters
|
Value
|
Battery
life
Size
Weight
|
Laser/LED source: 40/35 hours in Autotest, typical
124 x 81 x 25 mm / 4.9 x 3.2 x 1.0”
0.15 kg / 0.33 lb. Shipping
0.5 kg / 1.1 lb.
|
Operating
/ Storage
Relative
Humidity
Case
|
15 to 55 °C / -25 to 70 °C
0 ~ 95%
Polycarbonate with captive dust cap, 2.5-meter drop tested
|
Power
Multi-fiber
ID
Calibration
cycle
|
2 Alkaline AAA cells. Selectable auto-off, low battery
indicator
Up to 12 fibers
3 years
|
Class 1 or 2 Laser / LED infrared device. These are eye safe under all
circumstances.
650 nm VFL only is Class 2M. Warning! Eye hazard if viewed with magnifying
device. Compliant with IEC60825-1 and 21CFR1040.10.
Australian and international patents. Technical data is subject to
change without notice as part of our program of continuous improvements.
ORDERING
INFORMATION
Description
|
Part
number
|
Instrument,
Source 635 nm VFL Laser
Instrument, Source 650 nm VFL Laser
|
KI 9807A
KI 9808A
|
Instrument, Source 660 nm
LED
Instrument, Source
850-1300 nm LED
|
KI 9809AM
KI 9812A
|
Instrument,
Source 1310 nm Laser
Instrument,
Source 1310-1550 nm Laser
|
KI 9820A
KI 9822A
|
Instrument,
Source 1310-1550 nm Laser APC
Instrument,
source 1310-1625 nm Laser APC
|
KI 9822A-APC
KI9825A-APC
|
Instrument,
Source 1310-1490-1550 nm Laser
Instrument,
Source 1310-1490-1550 nm Laser APC
|
KI 9827A
KI
9827A-APC
|
Instrument,
Source 1310-1550-1625 nm Laser APC
Instrument,
Source 850 nm VCSEL
|
KI
9828A-APC
KI 9840A
|
Please enquire
for non-standard connectors, APC connector, and laser / LED wavelengths etc.
STANDARD
ACCESSORIES
Description
|
Quantity
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/SC
50 & 62.5 µm fiber mandrel wraps set (OPT701) for MM LED source
|
1
1
|
Quick guide
|
1
|
Soft carry pouch (OPT156)
|
1
|
Wrist strap
QA certificate
|
1
1
|
OPTIONAL ACCESSORIES
Description
|
Part number
|
Option,
accessories pack KI9000, includes:
i)
ST metal-free interchangeable connector adaptor (OPT040)
ii)
LC metal-free interchangeable connector adaptor (OPT076)
iii)Soft carry pouch (OPT156)
|
OPT148
quantity:
1
quantity:
1
quantity:
1
|
iv)AAA alkaline batteries
|
quantity:
2
|
This instrument is supplied with metal-free sleeve optical
interchangeable connector adaptors. The power meter works with both PC and APC
connectors. The visible laser connector ferrule type is fixed and customer
specified as either PC or APC. Green is associated with APC.
OPTIONAL
INTERCHANGEABLE CONNECTOR ADAPTORS
Description
|
Part number
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/FC
|
OPT051
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/LC, metal
body
|
OPT076
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/ST
|
OPT040
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/D4
|
OPT055
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/MU
|
OPT080
|
Option, Hybrid Adaptor, Ceramic Sleeve,
SC/LSA-DIN47256
|
OPT071
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/E2000
|
OPT060
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/E2000
Green
|
OPT060G
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/Universal
1.25 mm
|
OPT084
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/Universal
2.5 mm
|
OPT081
|
Option, Hybrid Adaptor, SC/POF multi
|
OPT0774
|
Option, Hybrid Adaptor, Metal Sleeve, SC/SMA 905/906
|
OPT082
|
Option, Hybrid Adaptor, Ceramic Sleeve, SC/F3000 or
LC Simplex, plastic body
|
OPT072
|
Note 4:For Mini Toslink, unterminated POF cable, HFBR series
(simplex and duplex), 2.5mm. The user turnsthe turret to the required hole
size. Actual hole size 3.85, 3.5, 3.2, 2.55, 2.4, 2.3 mm x 8.5 mm deep
The light
source is made for either PC and APC connectors at time of order. Universal
connector adaptors may result in reduced performance when used with a light
source.
History
Record
Revision
|
Date
|
Editor
|
Change Description
|
30
|
14/6/2017
|
TO Ng
|
OPTICAL
SPECIFICATIONS section:
- added output power(-13dBm) and accuracy (±2dB) @ 200um PCF.
- Added Note 3 to indicate condition for the output accuracy
specifications.
Reason